SOLUTION

One system.
Designed and built by us. Owned by you.

Our scope: everything in the data center - power, cooling, cabinets, fire protection - integrated into a turnkey system, prefabricated to your needs. Your scope: the silicon and the shell. That is the whole division of labor.

THE SYSTEM
FOUR LAYERS, ONE ARCHITECTURE.

A complete Power Dynamics system is built across four integrated layers. Each one manufactured in-house. None of them dependent on a vendor we do not control.

LAYER 01

Energy

Bring your own energy. Immersion-cooled BESS from 15 kW to 5 MW / 10 MWh, integrated with solar, wind, gensets, or the grid. Cells held within 2°C live 30% longer. Storage that arbitrages, firm renewables, and sells grid services while your compute runs.

Utility-scale immersion-cooled BESS
LAYER 02

Thermal

Sealed-tray single-phase immersion, cold plate, or air - and hybrids that upgrade over time. PUE 1.05-1.10 where air cooling fails at 30 kW per rack. Zero fire risk, zero water consumption, and 85% of the heat captured as a sellable product instead of a bill.

Sealed-tray immersion cooling cabinet
LAYER 03

Compute infrastructure

Prefab containers that are the data center: 20ft and 40ft integrated edge units, AIDC modules with IT cabinets, UPS power distribution, MV skids, generators, cooling towers. 10.8 kW/m² density, IP55, road or sea transport, ground installation on concrete or steel base.

40ft prefabricated computing container
LAYER 04

Intelligence

The AI-powered EMS that runs the other three as one machine: predictive balancing from 15 minutes to 72 hours ahead, single-cell monitoring, remote cell-level shutdown, automated grid-services participation. Designed and built to be handed over to your team.

AI EMS CONTROL LAYER BESSGRIDPV / WINDLOAD
Bamboo - the fastest growing structure in nature
Bamboo grows a meter a day and carries its own structure. It scales fast, and it bends without breaking. Your infrastructure could too. Modular, load-bearing, kind to what surrounds it
HOW IT WORKS

A system that feeds itself.

Power, cooling, and compute talk to each other through one control layer - and the waste of one becomes the input of another. RUHE (Re-Utilization of Heat Emissions) closes the loop.

LOOP 01

Cold from LNG cools the compute

At an LNG terminal, regasification throws away cold. We route it to the data center instead. A 10 MW facility with LNG cold energy covering 50% of cooling drops PUE from 1.3 to 1.18 - and to 1.095 at 100% coverage.

1.85 MW cooling power saved / 10 MW DC  ·  8,136.7 MWh/yr electricity
LOOP 02

Heat from compute vaporizes the LNG

The data center's captured waste heat does the vaporization work the terminal would otherwise burn fuel or seawater pumps for. On-site gas generation adds a third tier: waste heat from the gensets joins the loop.

1,383.2 MWh/yr seawater pump electricity saved
100 - 400°C
Process heat range: food, textile, paper, chemical
85%
Heat captured at $0.02/kWh
District heating
The data center becomes a thermal supplier
THE COMPARISON

Why immersion changes the economics.

Metric
Traditional air-cooled
Power Dynamics immersion
PUE
1.5 - 2.0
1.05 - 1.10
Deployment
12 - 24 months
6 - 9 months
Heat recovery
Minimal
85% capture at $0.02/kWh
Fire risk
Present
Zero (dielectric fluid)
Water use
Evaporative, continuous
Zero, closed loop
Scalability
Fixed capacity
Modular, incremental
HOW WE DELIVER

From specification to handoff, in parallel.

The prefab method compresses the schedule because manufacturing and site work happen at the same time.

01

Consultation

We start from your load profile, site, power source, and sovereignty constraints - coverage, capacity, cooling architecture, upgrade path. No template answer survives contact with a real site plan.

02

Design

Energy, thermal, and compute layers designed together, end to end, by one engineering org. No handoffs between vendors means no losses between the gaps.

Foundation + basic shell: 3 months
03

Manufacture

Prefab equipment built and pre-tested at our 230,000 m² campus while your site is prepared. 16 UL-certified facilities, 12 GWh of annual BESS capacity.

Prefab: 3-6 months, parallel to site prep
04

Install & handover

Plug-and-play installation, one month of testing, and your team takes operational control with the EMS. We stay on under support contract. Total: 6-9 months + 1 month testing, versus 18+ traditional.

CUSTOMER TYPES

Built for those who cannot afford to depend on someone else.

All-in-one AI node container

Compute operators & AI infrastructure funds

Time-to-token is the whole game

You have the GPUs, the offtakers, and the capital. What you do not have is 140 kW-per-rack thermal headroom and a grid queue that clears in 2029. We deliver the energy and thermal envelope in 6-9 months, upgradeable as the silicon generation turns - so your facility never strands.

Entry point30 MW AIDC, gas turbine + microgrid
Density10.8 kW/m², immersion to 140 kW racks
Utility-scale cold-plate BESS

Energy developers, IPPs & utilities

Storage that earns in four markets at once

Utility-scale BESS in cold-plate or immersion, 5 MW / 10 MWh blocks, firming renewables and selling frequency regulation, spinning reserve, and balancing. Immersion-cooled cells hold within 2°C - degradation stops eating your IRR. 600 MW+ already delivered to China Southern Power Grid.

Deployed3+ GWh across six continents
Cycles6,000+ to 80% (LFP)
IT container module

Colocators & data center operators

More compute per square meter, online maintenance

Sealed-tray immersion means a rack you can service without draining a tank - colo SLAs survive the retrofit. 264% space efficiency versus air-cooled lets you sell capacity you did not have. Noise at or under 62.6 dB keeps you inside urban limits.

RetrofitRack-only, three architectures
UptimeOnline maintenance, zero fire risk
20ft edge compute container

Enterprise, government & institutions

Sovereign compute on your own ground

Branch offices, smart city nodes, university research clusters, oil and gas fields, ports, backup data centers. The 20ft integrated container arrives with cooling, UPS, and battery backup inside one IP55 box - compute where you need it, on the power you have.

Formats20ft / 40ft, road or sea
SectorsEnterprise, gov, edu, energy, finance, transport, telecom

Own your compute and energy.

Tell us your load, your site, and your timeline. Engineering answers, not sales.

SEND US A MESSAGE →
Designed by Power Dynamics. Owned by you.