PRODUCTS

The whole stack. Every layer of it.

Not a teaser. Seven BESS systems, integrated edge compute containers, the full AIDC module family, sealed-tray immersion cooling, and the AI control layer - all manufactured in-house, all deployable as one system.

BESS Edge Compute AIDC Modules PDCool 6 AI EMS
BATTERY ENERGY STORAGE

Storage that earns when idle.

Residential to utility scale. Cold-plate or immersion liquid cooling. LFP chemistry rated 6,000+ cycles to 80%. Immersion-cooled cells hold within 2°C - a 30%+ lifecycle gain over traditional liquid cooling.

Residential all-in-one hybrid BESS 15 kW
Residential

All-in-One Hybrid

Off-grid homes, medical clinics, backup power. Integrated thermal management in a single cabinet.

Power15 kW
Energy30 kWh
C&I liquid-cooled modular BESS 60 kW 208 kWh
C&I · Cold plate

Liquid-Cooled Modular

Real estate, islands, peak shaving. Modular blocks that scale with the load.

Power60 kW
Energy208 kWh
C&I high-density immersion-cooled BESS 130 kW 261 kWh
C&I · Immersion

High-Density Liquid-Cooled

Compute co-location and constrained footprints. Immersion cells, tighter ΔT, longer life.

Power130 kW
Energy261 kWh
C&I grid-services BESS 130 kW 261 kWh cold plate
C&I · Cold plate

Grid Services Optimized

Frequency regulation and demand-charge reduction. Duty-cycled for grid markets.

Power130 kW
Energy261 kWh
Utility-scale cold-plate BESS 5 MW 10 MWh
Utility · Cold plate

Utility Cold-Plate

Grid transition, IPP projects, renewable firming. Containerized, MV-integrated.

Power5 MW
Energy10 MWh
Utility-scale immersion-cooled BESS 5 MW 10 MWh
Utility · Immersion

Utility Immersion

Compute-integrated storage with shared thermal architecture. The Meizhou-class system.

Power5 MW
Energy10 MWh
3.75 MWh containerized BESS
Utility · Container

3.75 MWh Container

High-capacity single-container block for utility and large C&I deployments.

Energy3.75 MWh
FormatISO container

All systems: LFP chemistry · all-in-one hybrid architecture with integrated thermal management · 6,000+ charge cycles to 80% · Zero Ignition Architecture with remote cell-level shutdown. Spec sheets: request download

EDGE COMPUTE INFRASTRUCTURE

A complete data center in a container.

Prefabricated integrated computing infrastructure in 20ft and 40ft ISO formats - immersion or cold-plate liquid cooling, UPS, immersion battery backup, in-row conditioning, monitoring. Deployed in months, not years.

40ft prefabricated integrated computing infrastructure
40ft · Immersion or cold plate

40ft Integrated Computing Container

Four liquid-cooled IT cabinets at up to 52 kW each, two communication and storage cabinets at up to 16 kW, modular UPS with immersion-cooled LFP backup, liquid cooling unit with 1+1 redundancy option.

Dimensions12192 × 2438 × 3800 mm
Weight27 t immersion / 22 t cold plate
20ft prefabricated integrated computing infrastructure
20ft · Immersion or cold plate

20ft Integrated Computing Container

Two liquid-cooled IT cabinets at up to 52 kW each, one communication and storage cabinet at up to 16 kW, the same UPS and immersion battery architecture as the 40ft - in half the footprint.

Dimensions6058 × 2438 × 3800 mm
Weight17 t immersion / 13 t cold plate
System parameterImmersion liquid coolingCold plate liquid cooling
Liquid-cooled IT cabinets4 × ≤52 kW (40ft) / 2 × ≤52 kW (20ft)4 × ≤52 kW (40ft) / 2 × ≤52 kW (20ft)
Communication / storage cabinets2 × ≤16 kW (40ft) / 1 × ≤16 kW (20ft)2 × ≤16 kW (40ft) / 1 × ≤16 kW (20ft)
Rack750 × 1200 × 2500 mm, 42U600 × 1200 × 2500 mm, 42U
UPSModular, immersion-cooled LFP battery, >15 min backupModular, immersion-cooled LFP battery, >15 min backup
CoolantSingle-phase dielectricEthylene glycol aqueous solution
Liquid cooling unit1 standard, 1+1 redundant optional · 380-400V ±10%, 50Hz1 standard, 1+1 redundant optional · 380-400V ±10%, 50Hz
In-row air conditioning380-400V ±10% · R410A380-400V ±10% · R410A
PDU3-phase 380Vac 80A · C13 / C19 (IEC60309)3-phase 380Vac 80A · C13 / C19 (IEC60309)
Protection / installationIP55 · ground install, concrete or steel baseIP55 · ground install, concrete or steel base
Operating altitude≤4000 m (derating above 1000 m)≤4000 m (derating above 1000 m)
MonitoringAccess control, video (≥7 days), temp/humidity, leak, fire alarm, battery statusAccess control, video (≥7 days), temp/humidity, leak, fire alarm, battery status
TransportRoad or seaRoad or sea

Environments: Class A/B/C (Class C not supported at temperatures ≤ -20°C).

APPLICATIONS

Where the containers go.

Enterprise branch offices and factories · government smart city and public safety · universities and research computing · oil and gas, mines, renewable sites · finance backup data centers · airports, railways, ports · telecom edge and disaster-recovery sites.

AIDC MODULES

Every block of the data center, prefab.

The full picture of what we offer: compute cabinets, power distribution, cooling, and facility systems - manufactured as modules, integrated as one turnkey system. Your scope is the silicon; ours is everything around it.

Immersion cooling server cabinet
Compute

Immersion Server Cabinet

Sealed-tray immersion cabinet for high-density GPU and HPC workloads. Online maintenance, zero fire risk.

AI integrated cabinet
Compute

AI Integrated Cabinet

Air, cold-plate, or immersion-cooled IT cabinets in one integrated family - configured to the rack density you actually run.

All-in-one AI node container
Compute

All-in-One AI Node Container

Portable edge inference: compute, cooling, and battery in one deployable node. Runs on site power or internal storage.

IT container module
Compute

IT Container Module

Modular server room in an ISO container. Stackable, relocatable, upgradeable - the anti-stranded-asset.

UPS power distribution container
Power

UPS Power Distribution Container

Grid power, main and auxiliary transformers, MV switch, capacitor compensation, UPS cabinets - one containerized chain.

Medium voltage skid
Power

MV Skid & Power Distribution

Medium-voltage connection and distribution skids, centralized or string PCS - matched to your grid interface.

Diesel generator container
Power

Diesel Generator Container

Backup generation in the same modular grammar. Waste heat joinable to the RUHE loop.

Distributed coolant distribution unit
Cooling

Distributed CDU

Coolant distribution at the row or rack. Primary/secondary annular pipeline architecture with redundancy options.

Closed cooling tower
Cooling

Closed Cooling Tower

Primary cold source with zero evaporative water loss. In-row conditioners, wind walls, and HVAC complete the facility system.

Family specs: ISO 40ft modules · prefabricated, stackable, modular · 10.8 kW/m² power density · 8.6 PFLOPS/m² · 6-9 month deployment vs 18+ traditional. Facility scope includes lighting, fire protection, monitoring, and fresh air systems.

Forest canopy
We build to be kind to nature. It is not a page on this website. It is the engineering constraint. Zero water · zero fire risk · 45,000 t CO2 avoided per year at Meizhou
PDCOOL 6 · IMMERSION COOLING

Sealed-tray, not open-tank.

The differentiator. Single-phase dielectric immersion in sealed vertical trays - servers and cells submerged without a tank. Pull a server without draining anything.

PDCool 6 sealed-tray immersion cabinet

PDCool 6

Proprietary in-house coolant · three architectures

Immersion, cold plate, or air - and rack-only retrofit for live facilities. Single-phase dielectric fluid with no third-party dependency. AI-driven safety controls with Zero Ignition Architecture across battery and compute layers. Chip-upgradeable: GPUs swap without re-engineering the cooling.

PUE1.05 - 1.10 subtropical
Space efficiency264% vs air-cooled
Fire / waterZero / zero
Noise≤ 62.6 dB
Compute density gainUp to 40% more per m²
AI-POWERED EMS

The intelligence layer across power, storage, and cooling.

One control plane for BESS, DC power, cooling, and compute load. Predictive, not reactive - and designed to be handed over.

Forecasting

Predictive balancing

Renewable generation versus compute load, from 15-minute spot to 72-hour ahead. Storage dispatches to price, not to panic.

Safety

Single-cell visibility

Every cell instrumented, every deviation flagged before it becomes a trend. ΔT held within 2°C for a 30%+ lifecycle gain.

Safety

Remote shutdown at the single cell

If a cell deviates, the EMS isolates and shuts it down at the individual cell level - remotely, before a thermal event can propagate. Zero Ignition Architecture: fire prevented by design, not by response.

Revenue

Automated grid services

Frequency regulation, spinning reserve, balancing markets - bid automatically. Storage earns while the compute runs.

Integration

One stack, one view

BESS, UPS, CDU, HVAC, and IT load on one dashboard. The system talks to itself so your operators do not have to.

Openness

Your EMS, our hardware

Prefer your own control system? Every Power Dynamics system is built to connect. Open interfaces hand full command to your EMS, SCADA, or BMS - your data stays on your systems, your operators keep the keys. Our EMS is the default, never a lock-in.

Need the spec sheets?

Every product family has a full technical datasheet. Request the pack and engineering will follow up.

REQUEST SPECS →
One Catalog. One Partner. One System.